Audio – PROAMP(I)-7X400 |
|
Typical of 7 Mono Channels: |
|
Output Power |
400 Watts per channel at 8 Ohms;
700 watts per channel at 4 Ohms |
|
Power Bandwidth |
5Hz to 45kHz -3dB |
|
Frequency Response |
20Hz to 20kHz ±0.1dB |
|
THD |
0.02% |
|
IMD |
0.05% |
|
S/N Ratio |
117dB A-weighted |
|
Crosstalk |
105dB |
|
Damping Factor |
>250 |
|
Gain |
23dB |
|
Input Sensitivity |
4 Vrms produces 400W into 8 Ohms |
Audio – PROAMP(I)-7X250 |
|
Typical of 7 Mono Channels: |
|
Output Power |
250 Watts per channel at 8 Ohms;
450 watts per channel at 4 Ohms |
|
Power Bandwidth |
5Hz to 45kHz -3dB |
|
Frequency Response |
20Hz to 20kHz ±0.1dB |
|
THD |
0.01% |
|
IMD |
0.05% |
|
S/N Ratio |
115dB A-weighted |
|
Crosstalk |
105dB |
|
Damping Factor |
>250 |
|
Gain |
23dB |
|
Input Sensitivity |
3.2 Vrms produces 250W into 8 Ohms |
Communications |
|
Ethernet |
For control, console, and pairing with PSPHD; 10/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full/half duplex, TCP/IP, UDP/IP, CIP, DHCP |
|
Cresnet |
For control and console, Cresnet slave |
Connectors |
|
LAN |
(1) 8-wire RJ45 with 2 LED indicators;
10Base-T/100Base-TX Ethernet port;
Green LED indicates link status;
Amber LED indicates Ethernet activity;
Straight-thru LAN cable included for direct connection to PSPHD |
|
NET |
(2) 4-pin 3.5mm detachable terminal blocks;
Cresnet slave ports, paralleled |
|
120V~60Hz MAX 12A
(top, PROAMP-7X250 and PROAMP-7X400) |
(1) IEC C14 male chassis plugs, main power input #1;
Mates with removable power cord (included);
Includes a 15 Amp circuit breaker;
Requires an independent 15 Amp, 120 Volt AC feed |
|
240V~50Hz MAX 6A
(top, PROAMPI-7X250 and PROAMPI-7X400) |
(1) IEC C14 male chassis plugs, main power input #1;
Mates with removable power cord (included);
Includes an 8 Amp circuit breaker;
Requires an independent 8 Amp, 220-240 Volt AC feed |
|
120V~60Hz MAX 12A
(bottom, PROAMP-7X400 only) |
(1) IEC C14 male chassis plug, main power input #2;
Mates with removable power cord (included);
Includes a 15 Amp circuit breaker;
Requires an independent 15 Amp, 120 Volt AC feed; must be a separate circuit from power input #1 |
|
240V~50Hz MAX 6A
(bottom, PROAMPI-7X400 only) |
(1) IEC C14 male chassis plug, main power input #2;
Mates with removable power cord (included);
Includes an 8 Amp circuit breaker;
Requires an independent 8 Amp, 220-240 Volt AC feed; must be a separate circuit from power input #1 |
|
INPUTS L, R, SL, SR, SBL, SBR, C |
(7) 3-pin XLR female;
Balanced line-level audio inputs;
Input Impedance: 24k Ohms balanced;
Maximum Input Level: 4 Vrms balanced |
|
OUTPUTS L, R, SL, SR, SBL, SBR, C |
(7) 2-pin 7.62mm 41A detachable terminal blocks;
Power amplifier outputs;
Wire Size: Terminals accept up to 10 AWG |
|
G |
6-32 screw, chassis ground lug |
Controls & Indicators |
|
PWR 1 |
(1) green LED, indicates power switch is enabled and power is present at the upper power input |
|
PWR 2
(PROAMP[I]-7X400 only) |
(1) green LED, indicates power switch is enabled and power is present at the lower power input |
|
NET |
(1) amber LED, indicates communication with Cresnet system |
|
TEMP |
(1) red LED, indicates an over-temperature condition |
|
SIGNAL L, R, SL, SR, SBL, SBR, C |
(7) green LEDs, indicate signal presence on the corresponding channel |
|
CLIP L, R, SL, SR, SBL, SBR, C |
(7) amber LEDs, indicate a clipping condition on the corresponding channel |
|
FAULT L, R, SL, SR, SBL, SBR, C |
(7) red LEDs; indicate over-temperature, over-current, over or under power supply voltage, or DC offset condition on the corresponding channel |
|
RESET |
(1) miniature pushbutton, clears all channel fault indications if condition is resolved |
|
Power |
(1) toggle switch, enables/disables amplifier power |
|
NETWORK/DIRECT (rear) |
(1) slide switch, selects whether connection to PSPHD is via LAN or direct connection |
|
OVERRIDE/SETUP (rear) |
(1) miniature pushbutton and (1) red LED, used for touch-settable ID (TSID) in conjunction with Crestron Toolbox™ software, for activating override mode for testing, and for pairing with PSPHD |
Power Requirements |
|
Main Power, PROAMP-7X400 |
2 x 12 Amps @ 120 Volts AC, 60 Hz;
Important: Requires two independent 15 Amp circuits! |
|
Main Power, PROAMP-7X250 |
12 Amps @ 120 Volts AC, 60 Hz |
|
Main Power, PROAMPI-7X400 |
2 x 6 Amps @ 220-240 Volts AC, 50 Hz;
Important: Requires two independent 8 Amp circuits! |
|
Main Power, PROAMPI-7X250 |
6 Amps @ 220-240 Volts AC, 50 Hz |
|
Cresnet Power Usage |
none |
Environmental |
|
Temperature |
41° to 104°F (5° to 40°C) |
|
Humidity |
10% to 90% RH (non-condensing) |
|
Heat Dissipation,
PROAMP(I)-7X400 |
650 BTU/Hr (400W@8Ω), 1100 BTU/Hr (700W@4Ω) |
|
Heat Dissipation,
PROAMP(I)-7X250 |
350 BTU/Hr (250W@8Ω), 625 BTU/Hr (400W@4Ω) |
Enclosure |
|
Chassis |
Metal, vented sides, ultra-quiet speed-controlled fan cooling |
|
Front Panel |
Aluminum with plastic overlay |
|
Mounting |
Freestanding or 5U 19-inch rack-mountable (detachable feet, rack ears, and handles are pre-installed) |
Dimensions |
|
Height |
9.24 in (235 mm);
8.70 in (221 mm) without feet |
|
Width |
19.0 in (483 mm);
17.28 in (439 mm) without rack ears |
|
Depth |
21.14 in (537 mm);
18.36 in (467 mm) without front and rear handles |
Weight |
|
PROAMP(I)-7X400 |
108 lbs (49 kg) |
|
PROAMP(I)-7X250 |
105 lbs (48 kg) |