DESIGN IDEAS

Designs inspirations for enterprises, education, government, and residential

Learn More

Increase your efficiency, boost your productivity, and stay ahead of the competition with industry-leading training from the Crestron Technical Institute

Learn More

Increase your efficiency, boost your productivity, and stay ahead of the competition with industry-leading training from the Crestron Technical Institute

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

GREAT TEAMS OWN THE MOMENT

The New York Giants Draft Room presented by Crestron

Learn More

Explore moments made possible with DM NVX® technology.

Learn More

GREAT TEAMS OWN THE MOMENT

The New York Giants Draft Room presented by Crestron

Learn More

Everything in the home is controlled with ease on one intelligent platform.

Learn More

GREAT TEAMS OWN THE MOMENT

The New York Giants Draft Room presented by Crestron

Learn More

Missed DM NVX AV-over-IP Week?

The good stuff from our week-long celebration of innovation is available! Catch webinars, techinars, and other opportunities to learn.

View our entire
product catalog

Dedicated solutions for
the modern workplace.

See the Catalog

Online help

Quickly find the answers and resources you need for all things Crestron. Ask questions, manage previously asked questions, access FAQs, and more.

Learn More

Online help

Quickly find the answers and resources you need for all things Crestron. Ask questions, manage previously asked questions, access FAQs, and more.

Learn More

Looking for a specific product?

See the Catalog

PC-100

Power Conditioner 100

Discontinued

This product has been discontinued. Please contact Crestron True Blue Support at 1-888-CRESTRON for a replacement solution or more information.

A rack-mountable 15A, 120V AC power conditioner and surge protector for professionally installed AV and IT systems.

The PC-100 is a professional grade, rack-mountable power conditioner designed to provide 120 Volt AC power distribution, switching, surge protection, and noise filtering for Crestron® control systems, AV systems, computers, and other equipment. Eight switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected and filtered. The switched outlets are arranged in four banks of two, two of which are turn-on delayed to prevent dangerous transients during power-up.

Power Conditioning
A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-100 includes the following power conditioning features:

  • Surge Protection — Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances
  • Under/Over Voltage Cutoff — Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range
  • Thermal Breaker — Disrupts power to all outlets in case of an overload condition
  • EMI/RFI Noise Filtering — Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality
  • Wiring Fault Detection — Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [1]

Three-Stage Sequential Turn-On Delay
The switched outlets on the PC-100’s rear panel are arranged in four banks, with two outlets per bank. When the front panel switch is turned on, or when power is applied to the main line input following a power outage or through an externally switched circuit, the first two banks of outlets turn on immediately, the third bank turns on following a one second delay, and the fourth bank turns on following a two second delay. This ensures that the connected equipment gets powered up in proper order, preventing dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up.

Protection Status Output
A contact closure output is included to provide notification to a control system or other equipment if the internal surge protection circuit is compromised due to an extreme transient voltage surge. In the unlikely event of such a condition, the PROTECTION output presents a low-voltage contact closure signal and all power to the rear panel outlets is switched off. Protection status is also indicated via LEDs on the front panel.

UL® 1449 Certified
The PC-100 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).

 
Key Features
  • Rack-mountable power conditioner
  • Eight switched rear panel outlets
  • Three-stage sequential turn-on delay
  • One unswitched front panel outlet
  • Professional grade surge protection
  • UL® 1449 Type 3 Listed
  • Thermal breaker overload protection
  • Over-voltage and under-voltage cutoff
  • EMI and RFI noise filtering
  • Wiring fault detection [1]
  • Front panel main power switch and status indicators
  • Protection status contact closure output
  • Single-space 19 inch rack-mountable
  • Rated 15 Amps at 120 Volts AC
  1. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-100 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-100 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.

This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at www.crestron.com/salesreps or by calling 800-237-2041.

The specific patents that cover Crestron products are listed online at: patents.crestron.com.

Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource.

Crestron and the Crestron logo are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries.  UL is either a trademark or registered trademark of UL LLC in the United States and/or other countries.  Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. ©2016 Crestron Electronics, Inc.

 
Power Conditioner
  Maximum Output Current, Total 15 Amps @ 120 Volts AC
  Maximum Output Current, Per Outlet/Bank 15 Amps @ 120 Volts AC (subject to a maximum total output current of 15 Amps for all outlets combined)
  Filtration 40 dB @ 100 kHz, 50 dB @ 300 kHz, with 50 Ohm load
  Surge Protection Modes L-G, L-N, N-G
  Surge Protection Shutoff Shuts off rear outlets if surge protection is compromised
  Energy Dissipation 2000 Joules per Mode
  Clamping Voltage 370 Volts
  Clamping Time 1 ns
  Wiring Fault Detection Shuts off rear outlets if a wiring fault is detected at the input [1]
  Under-Voltage Cutoff Shuts off rear outlets if input drops below 93 Volts
  Over-Voltage Cutoff Shuts off rear outlets if input exceeds 135 Volts
  Turn-On Delay SWITCHED ON 1: 0 seconds;
SWITCHED ON 2: 0 seconds;
DELAYED ON 1: 1 second;
DELAYED ON 2: 2 seconds
Power
  Line Power 15 Amps @ 120 Volts AC, 60 Hz
  Power Consumption ~10 Watts typical, 30 Watts maximum (not including load)
Connectors
  120V~ 15A 60Hz (1) Attached 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug;
Line power input
  SWITCHED ON 1 (2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 0 seconds
  SWITCHED ON 2 (2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 0 seconds
  DELAYED ON 1 (2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 1 second
  DELAYED ON 2 (2) NEMA 5-15R AC power outlets;
Switched 120 Volt AC power outlet bank;
Turn-On Delay: 2 seconds
  PROTECTION (1) 2-pin 3.5 mm detachable terminal block;
Normally open, isolated relay;
Rated 1 Amp, 30 Volts AC/DC;
Provides a dry contact closure if surge protection is compromised
  G (1) 6-32 screw, chassis ground lug
  ALWAYS ON (front) (1) NEMA 5-15R AC power outlet;
Unswitched 120 Volt AC power outlet
Controls & Indicators
  PWR (1) Bi-color green/amber LED, indicates line power is present and the power switch is on (green) or off (amber)
  FAULT (1) Red LED, indicates any of the following fault conditions: surge protection is compromised, line and neutral are reversed, or no ground is detected [1]
  PROTECT (1) Green LED, indicates surge protection is fully functional
  SHUTDOWN (1) Amber LED, indicates power to the rear outlets is shut off due to an over-voltage, under-voltage, line input miswire, missing ground, or compromised surge protection fault condition
  Power Switch (1) Rocker switch, "On" position initiates turn-on delay sequence to the rear panel outlets, "Off" position turns all rear outlets off immediately
  THERMAL BREAKER (rear) Disrupts power to all outlets in case of an overload condition, press to reset after overload condition is resolved
Environmental
  Temperature 32° to 113° F (0° to 45° C)
  Humidity 10% to 90% RH (non-condensing)
  Heat Dissipation 34 BTU/hr typical;
102 BTU/hr maximum
Construction
  Chassis Steel, black finish
  Front Panel Extruded aluminum, black finish, polycarbonate label overlay
  Mounting 1 RU 19-inch rack-mountable (rack ears included)
Dimensions
  Height 1.73 in (44 mm) without feet
  Width 17.32 in (440 mm);
19.00 in (483 mm) with rack ears
  Depth 10.56 in (269 mm)
Weight
  8.2 lb (3.8 kg)
Compliance
  UL 1449 Type 3 Listed
In the CSEA region, available in Macau & Hong Kong only.
Click here to search product certificates.
  1. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-100 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-100 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.

This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at www.crestron.com/salesreps or by calling 800-237-2041.

The specific patents that cover Crestron products are listed online at: patents.crestron.com.

Certain Crestron products contain open source software. For specific information, please visit www.crestron.com/opensource.

Crestron and the Crestron logo are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries.  UL is either a trademark or registered trademark of UL LLC in the United States and/or other countries.  Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. ©2016 Crestron Electronics, Inc.

Pricing Region Select
Please select your region below to see the appropriate Advertised Pricing.
Powered by Translations.com GlobalLink Web SoftwarePowered by GlobalLink Web